TPR-5000  COMPUTERIZED FULL-FUNCTIONAL VENTILATOR


* Frequency(IPPV): 6~60 breaths/min
* Tidal volume : 100~1500 ml/time
* I/E ratio: 1 : 1~ 1 : 3
* Alarm for upper-limitation of airway pressure: 1.0~6.0KPa
* Alarm for lower-limitation of airway pressure: 0~2.0KPa
* Output oxygen Concentration: 21%~100% adjustable
* Ventilation modes: Inspiratory pause, CPAP, IPPV, IPPB, PEEP, SIMV, IPPV+SIGH, First-aid ventilation

      
TPR-4000 COMPUTERIZED MULTI-FUNCTIONAL VENTILATOR

* Frequency (IPPV):6~60 breath/min
* SIMV frequency: 1~15 breaths/min
* I/E ratio: 1 : 1~ 1 : 3
* Tidal volume : 100~1500 ml
* Alarm for upper-limitation of airway pressure: 1.0~6.0KPa
* Alarm for lower-limitation of airway pressure: 0~2.0KPa
* Ventilation modes: Inspiratory pause, IPPV, IPPB, SIMV, PEEP, CPAP, IPPV+SIGH, First-aid ventilation

      
TKR-300JII COMPUTERIZED HIGH-FREQUENCY FIRST-AID VENTILATOR

* Frequency: 10~150 breaths/min
* I/E ratio: 1:1~1:3 and inverse ratio
* Driving Pressure : 0~0.15MPa
* Storage battery: 4Ah, 12V .Can be charge repeatedly.
* Alarm: Alarm with light and sound when power failure or no gas, alarm lasting 6 seconds
* Maximum Oxygen Concentration: 85%
* Ventilation Modes: HFJV (High Frequency Jet Ventilation); CPAP (Continuous positive airway pressure), Constant volume ventilation; HFJV+SIGH

      
TKR-400A COMPUTERIZED HIGH-FREQUENCY VENTILATOR FOR INFANT


* Frequency: 10~150 breaths/min
* I/E ratio: 1:1~ 1:3 and inverse ratio
* Driving Pressure : 0~60KPa 
* Storage Battery: 4Ah, 12V. Can be charge repeatedly.
* Alarm: Alarm with sound and light when power failure or no oxygen for 6 seconds, or the airway pressure is over 1Kpa±0.2Kpa
* Oxygen Concentration : 40%~90%(without gas source) 21%~90%(with gas source)
* Ventilation Modes: HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure); Pro I and Pro II ventilation ; HFJV+SIGH;HFJV+PEEP; Manual ventilation.

      
TKR-400(T) HIGH-FREQUENCY JETTING VENTILATOR


* Frequency: 10~150 breaths/min
* I/E ratio: 1 : 1~ 1 : 4 and inverse ratio
* Alarm: Alarm with light and sound for power failure, alarm lasting 6 seconds if no oxygen
* Maximum Oxygen Concentration: 85%
* Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure);ProI and ProII ventilations; HFJV+SIGH, HFJV+PEEP and Manual ventilation.

      
TKR-300CG HIGH-FREQENCY JETTING VENTILATOR

Frequency: 10~150 breaths/min
* I/E ratio: 1:1~ 1:3 and Inverse ratio
* Driving Pressure : 0~150KPa 
* Alarm: Alarm with light and sound for no gas or power failure or airway pressure upper-limitation
* Maximum Oxygen Concentration: 85%
* Inner Battery: 4Ah 12V
* Ventilation Modes:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure); Process I and Process II ventilation; HFJV+SIGH;, Manual ventilation.

      
TKR-300CG HIGH-FREQUENCY JETTING VENTILATOR

* Frequency: 10~150 breaths/min
* Driving Pressure : 0~0.15 MPa
* I/E ratio: 1:1~1:3 and inverse ratio
* Inner battery: Can be used four hours independently.

      
TPR-12 PAINLESS CHILDBIRTH ANTALGIC GAS INSPIRATOR

* Inspiratory flux: 10~1000 ml/time
* Inspiratory modes: Independent and synchronous inspiration with digital flow presetting
* Alarm with light and sound of power failure,and lasting for more than 30s.
* Gas proportion: N2O:O2=1:1
* Decompressor output pressure limit :  0.2MPa
* LED digital flow display

      

 

15 products 2 pages Page1 Page2

 